measure of a material or component's ability to resist fire spread
A fire rating is a technical classification measuring a material or system's reaction to fire or fire resistance. In the UK cladding industry, these ratings determine the suitability of external wall components based on building height and use.
Last updated
On this page
Fire Rating
Definition and Scope of Fire Rating
In the context of the UK built environment, a fire rating is a measure of a material or component's ability to resist fire spread. Within the cladding industry, this term is frequently utilised as a shorthand to describe how individual products, or entire external wall systems, perform when subjected to standardised thermal conditions. It is not a single value but rather a classification derived from rigorous testing protocols designed to quantify specific performance characteristics.
For external cladding, fire ratings typically address two distinct but related criteria: reaction to fire and fire resistance. The former evaluates how a material contributes to the development and spread of a fire—focusing on ignitability, heat release, and smoke production—while the latter measures how long a construction element can maintain its structural integrity, insulation, and integrity against flames. In the assessment of cladding systems, the reaction to fire classification is often the primary metric used to determine suitability for specific building heights and uses.
The Role of Fire Ratings in Cladding Assessment
Fire ratings are central to the lifecycle of cladding testing, repair, and replacement. When a building undergoes a facade assessment, such as an EWS1 (External Wall System) survey or a Fire Risk Appraisal of External Walls (FRAEW), the existing materials are identified and their original fire ratings verified. This often involves reviewing Operation and Maintenance (O&M) manuals, technical data sheets, or, where documentation is absent, performing laboratory testing on samples extracted from the building.
In remediation projects, the fire rating of proposed replacement materials dictates the design strategy. Because cladding systems are comprised of multiple layers—including the outer rainscreen, insulation, cavity barriers, and the substrate—the fire rating of the individual components must be considered alongside the performance of the system as a whole. A high-performing rainscreen panel may not compensate for a lower-rated insulation material if the overall assembly does not meet the necessary threshold for the building’s specific risk profile.
Regulatory Context in England and Wales
The regulatory framework governing fire ratings has undergone significant refinement, particularly following changes to the Building Regulations 2010. For residential buildings in England and Wales over a certain height, the regulations mandate the use of materials that achieve specific European Classifications (Euroclasses). Approved Document B (Fire Safety) serves as the primary guidance for demonstrating compliance with these requirements.
The transition from national classes (such as Class 0) to the European standard (BS EN 13501-1) has standardised how fire ratings are communicated. This system provides a comprehensive classification from A1 (non-combustible) to F (easily flammable). In current practice for high-rise residential buildings, the focus is predominantly on achieving Class A1 or A2-s1, d0. These ratings indicate that the material makes no or very limited contribution to a fire, with minimal smoke production and no flaming droplets.
External Wall Systems and Performance Criteria
A fire rating is rarely a static attribute of a building’s facade; rather, it is a reflection of how the building fabric behaves under thermal stress. External wall systems are complex assemblies where the interaction between components is critical. For instance, the presence of a ventilated cavity requires fire ratings to be considered in conjunction with the performance of cavity barriers, which are designed to close the gap in the event of a fire.
| Classification | Contribution to Fire | Typical Requirement Context |
|---|---|---|
| A1 | Non-combustible | Highest safety tier; no contribution to fire |
| A2 | Limited-combustible | Negligible contribution; restricted smoke/droplets |
| B - D | Combustible | Varying degrees of contribution; restricted use |
| E - F | Highly combustible | Generally unsuitable for external wall systems |
The distinction between a "product" rating and a "system" rating is a vital technical nuance. A product may have an A2 rating in isolation, but its performance within a specific build-up—including adhesives, fixings, and membranes—must be validated. In some instances, large-scale system testing (such as BS 8414) is employed to assess how the entire wall assembly performs, providing a more holistic fire rating than individual component tests alone.
Fire Rating
Guidance for Building Owners and Managers
For those responsible for the management of multi-storey buildings—including Resident Management Companies (RMC) and Right to Manage (RTM) directors—understanding fire ratings is essential for informed decision-making. The fire rating of the cladding is a fundamental factor in the building’s overall fire risk assessment and can influence insurance premiums, mortgageability, and the necessity for interim safety measures.
Building owners must ensure that any technical information regarding fire ratings is provided by a competent professional, such as a fire engineer or a specialist facade consultant. It is the responsibility of these professionals to interpret how the fire ratings of the existing facade align with current safety standards. When remediation is required, managers must oversee a process where the specified materials not only meet the required fire rating on paper but are also installed correctly to maintain the integrity of that rating in practice.
Common Misunderstandings and Nuances
A frequent misconception is that a "fire rated" material is entirely "fireproof." In professional terms, no material is truly fireproof; rather, it has a measured level of resistance or a specific reaction to fire under test conditions. Another common point of confusion is the difference between "Class 0" and "Class A2." Class 0 was a historic British Standard classification that primarily measured surface spread of flame, whereas the modern Euroclass A2 rating involves more stringent criteria regarding the internal combustibility of the material.
Furthermore, fire ratings are often conflated with "fire stopping." While a fire rating describes a material's property, fire stopping refers to the physical seals and barriers installed to prevent the passage of fire through openings or joints. A building may utilize materials with high fire ratings, but if the fire stopping is incorrectly specified or installed, the overall fire safety of the building fabric may be compromised.
Related Terminology and Standards
To fully comprehend the implications of a fire rating, it is necessary to be familiar with several related technical terms:
- Euroclass System (BS EN 13501-1): The prevailing standard for classifying the reaction to fire of construction products.
- Non-combustible: A term strictly reserved for materials that achieve an A1 rating, meaning they do not contribute to fire growth even in fully developed fires.
- Limited-combustible: Materials that achieve an A2 rating; they have a very low heat of combustion but are not technically non-combustible.
- Integrity (E): In fire resistance testing, the ability of a component to prevent the passage of flames and hot gases.
- Insulation (I): The ability of a component to restrict the temperature rise on the non-exposed side.
- Combustibility: A general term for the capacity of a substance to burn, which is quantified through specific fire rating tests.
The application of these ratings is always site-specific. The height of the building, its occupancy type, and its proximity to other structures all influence which fire ratings are required by law and which are recommended for long-term risk management. Because the regulatory landscape and material sciences continue to evolve, the interpretation of fire ratings remains a task for qualified experts who can assess the specific technical requirements of an individual building’s external wall system.