Cladding Testing

Glossary · Two-word term

Ews1 External

In short

certificate confirming external wall fire safety assessment for residential buildings

The EWS1 (External Wall System) process is a technical framework used in the UK to assess the fire safety of residential building envelopes for valuation purposes, resulting in a graded report signed by a qualified professional.

Last updated

Appears 103 times across this site

Definition and Purpose of the EWS1 External Wall System Process

The term EWS1 refers to the External Wall System 1 process, a technical framework introduced by the Royal Institution of Chartered Surveyors (RICS) in late 2019. It was developed to address valuation difficulties for high-rise residential buildings where the fire performance of the building envelope was unknown or unverified. In the context of cladding testing and remediation, the EWS1 form serves as a recorded outcome of a professional assessment regarding the fire safety of a building’s external wall construction.

It is important to distinguish the EWS1 from a generic safety certificate or a statutory building control document. Instead, it is a valuation tool intended to provide lenders with clarity regarding the potential for significant remedial costs associated with the external wall system. While it is not a legal requirement under building regulations, it has become a standard requirement in the UK mortgage market for buildings within certain risk categories.

Technical Components of the External Wall System

An EWS1 assessment involves a detailed physical inspection of the building fabric. This extends beyond the visible outer cladding panels to include the entire build-up of the external wall. A competent professional typically examines several interconnected components:

  • Outer Cladding: The visible rainscreen, which may be composed of Aluminium Composite Material (ACM), Metal Composite Material (MCM), High-Pressure Laminate (HPL), or various masonry and timber products.
  • Insulation: The thermal layer situated behind the cladding, which may be combustible (such as certain plastics or foams) or non-combustible (such as mineral wool).
  • Cavity Barriers and Fire Stops: Essential components designed to prevent the spread of fire and smoke through the concealed voids behind the cladding.
  • Substructure and Fixings: The rails, brackets, and frames that secure the system to the building’s primary structure.
  • Attachments: Balconies, solar shading, and other features that are integrated into or attached to the external wall.

The assessment requires a review of "as-built" drawings and operation and maintenance (O&M) manuals, supplemented by intrusive site investigations where necessary. These investigations often involve opening "sampling pits" to verify that the internal construction matches the original design specifications.

The EWS1 Grading System

The outcome of an EWS1 assessment is categorised into two main ratings, A and B, which are further divided based on the presence of combustible materials and the necessity for remedial work.

RatingDescription
Option AExternal wall materials are unlikely to support combustion.
A1No combustible materials are present in the external wall.
A2Combustible materials are present but an assessment confirms they do not pose an undue risk.
A3Combustible materials are present and remedial works are likely required.
Option BCombustible materials are present in the external wall.
B1The fire risk is sufficiently low that no remedial works are required.
B2An adequate standard of fire safety is not achieved; remediation is necessary.

A rating of A3 or B2 generally signifies that the building requires some form of intervention to meet the standards required by lenders, which often triggers the planning phase for cladding replacement or repair.

Regulatory Context in England and Wales

The EWS1 process exists alongside a broader landscape of UK fire safety legislation. While the EWS1 is a valuation industry product, it is influenced by the Building Safety Act 2022 and the Fire Safety Act 2021. The Fire Safety Act 2021 clarified that for any building containing two or more sets of domestic premises, the Regulatory Reform (Fire Safety) Order 2005 applies to the building’s structure, external walls (including cladding, balconies, and windows), and all common parts.

This legislative framework requires the "Responsible Person"—typically the building owner, freeholder, or management company—to conduct a Fire Risk Assessment (FRA) that accounts for the external wall system. In many cases, an EWS1 assessment is used to inform the broader Fire Risk Appraisal of External Walls (FRAEW) conducted under the British Standard PAS 9980:2022. While the EWS1 is focused on valuation, the PAS 9980 provides a more comprehensive methodology for assessing the risk of fire spread via external walls.

Professional Requirements and Responsibility

The EWS1 form must be completed by a qualified professional with the appropriate level of expertise. For Option A ratings, the signatory must be a member of a relevant professional body within the construction industry. For Option B ratings, which involve a higher degree of fire engineering judgement, the signatory must be a chartered professional specialising in fire engineering or a highly qualified member of a relevant professional body with specific expertise in fire safety.

For Resident Management Companies (RMC) and Right to Manage (RTM) directors, understanding the professional indemnity insurance (PII) of the assessor is critical. There has historically been a shortage of professionals with both the technical competency and the necessary insurance coverage to sign these forms, leading to delays in the assessment process.

Common Misunderstandings and Limitations

A frequent misconception is that an EWS1 form is valid indefinitely. In practice, the document is generally considered valid for five years from the date of signature, or until significant changes are made to the building’s external wall system. Furthermore, an EWS1 form applies to an entire block; it is not issued for individual flats.

Another misunderstanding is that a "failed" EWS1 (ratings A3 or B2) automatically renders a building "unsafe." The EWS1 is a risk-based assessment for lending purposes. A building may require remedial work to satisfy a lender's risk appetite while remaining habitable under the guidance of the local Fire and Rescue Service, potentially with interim measures such as a "waking watch" or an upgraded fire alarm system in place.

Finally, the EWS1 process is not intended for buildings where the external wall is composed entirely of non-combustible masonry, such as traditional brick-and-block construction without cladding attachments. RICS guidance provides specific criteria for when an EWS1 is actually required, based on building height and the percentage of the facade covered by specific materials.

The terminology surrounding external wall assessments is frequently updated as policy evolves. Professionals often refer to the following:

  • PAS 9980:2022: The British Standards Institution code of practice for the fire risk appraisal of external wall profiles. It is increasingly becoming the technical foundation upon which EWS1 assessments are based.
  • FRAEW: Fire Risk Appraisal of External Walls. This is the technical report generated following a PAS 9980 assessment.
  • Cladding Remediation Scheme: Various government-funded programmes designed to address the costs of replacing unsafe cladding on high-rise residential buildings.
  • Building Safety Fund (BSF): A UK government fund established to cover the cost of replacing unsafe non-ACM cladding systems on residential buildings over 18 metres.

In summary, the EWS1 external wall system process remains a pivotal element of the UK housing market, bridging the gap between technical fire safety engineering and the financial requirements of the lending industry. Its execution requires a rigorous, evidence-based approach to the building fabric and a clear understanding of the prevailing regulatory environment.

Rope Access Facade Cleaning on Stone BuildingRope access technician in harness power washes a stone building facade above a wrought iron balcony.rope access technician cleaning stone building facade