Cladding Testing

Glossary · Single word

Structural

In short

Relating to the basic framework or essential supporting parts of a building

The term structural refers to the essential framework and load-bearing components of a building. In cladding, it encompasses the primary frame, secondary sub-frames, and fixings that must safely resist and transmit forces such as wind pressure and material weight.

Last updated

Appears 1,004 times across this site

Definition and Technical Scope

In the context of the built environment and cladding systems, the term "structural" refers to elements relating to the basic framework or essential supporting parts of a building. It identifies components designed to resist and transmit loads—such as dead loads (the weight of the building itself), live loads (occupants and furniture), and environmental loads (wind, snow, and seismic activity)—to the ground via the foundations.

Within an external wall system, structural considerations are not limited to the primary frame (such as steel beams, reinforced concrete slabs, or masonry). The term also encompasses the secondary structural elements, including the sub-frame, rails, brackets, and fixings that secure the cladding to the building. While the cladding panels themselves may be termed 'non-structural' in the sense that they do not support the building’s primary gravity loads, they are structural in their capacity to resist wind suction and transfer those pressures to the primary frame.

Structural Considerations in Cladding Assessment

When conducting cladding testing or intrusive surveys, the structural integrity of the external wall system is a primary area of investigation. Engineers and surveyors examine how the system is anchored to the building substrate. This involves assessing the condition of fixings, the presence of corrosion in metal components, and the adequacy of the load path from the external leaf back to the primary structure.

In repair and replacement work, structural analysis determines whether an existing frame can support new, potentially heavier, non-combustible cladding materials. For example, replacing a lightweight composite panel with a solid metal or terracotta alternative may increase the dead load on the secondary structure. Professionals must calculate whether the original brackets and rails possess the structural capacity to accommodate this change or if a new support system is required to maintain the stability of the building envelope.

Relationship to Building Fabric and External Walls

The building fabric functions as a holistic assembly where structural performance is inextricably linked to thermal and moisture management. The external wall system must maintain its structural stability while undergoing thermal expansion and contraction. If a system is not designed to accommodate these movements, internal stresses can lead to the failure of fixings or the deformation of panels.

Structural interactions also occur at the interfaces between different building elements, such as where cladding meets window apertures or roof parapets. In these areas, the secondary structure must be robust enough to maintain the airtightness and weatherproofing layers of the building fabric. Any degradation of the structural components, such as the rusting of steel studs due to water ingress, can compromise the long-term viability of the entire external wall assembly.

Regulatory and Process Context in England and Wales

The regulatory framework in England and Wales places significant emphasis on structural stability. The Building Regulations 2010, specifically Requirement A1 (Loading), mandates that buildings must be designed and constructed so that the combined dead, imposed, and wind loads are sustained and transmitted to the ground safely. This applies to both the primary structure and the cladding systems attached to it.

Under the Building Safety Act 2022 and the associated secondary legislation, the "Structural Safety" of a building is one of the two pillars of "building safety risks" (the other being fire safety) for higher-risk buildings. During the design and construction phases, or when undertaking significant remedial works, dutyholders must demonstrate that structural risks have been identified and managed. This often involves the submission of structural calculations and specifications to the Building Safety Regulator or a relevant building control body to ensure the proposed works meet the functional requirements of the regulations.

Guidance for Building Owners and Managers

For building owners, managing agents, and directors of Resident Management Companies (RMC) or Right to Manage (RTM) companies, understanding the structural nature of cladding is vital for long-term asset management. Maintenance regimes should include periodic inspections of the external wall’s structural components. Signs of potential structural distress may include:

  • Misalignment or bowing of cladding panels.
  • Visible corrosion or "tea staining" on metal rails and fixings.
  • Cracking in the substrate or around anchor points.
  • Excessive vibration or noise during high wind events.

When commissioning an EWS1 (External Wall System) assessment or a PAS 9980 appraisal, the structural competence of the system is often considered alongside its fire performance. If remediation is required, the structural implications of the proposed replacement materials must be factored into the project's technical and financial planning from the outset.

Common Misunderstandings

A frequent misunderstanding is the belief that because a cladding panel is "non-load-bearing," its structural role is negligible. In reality, the cladding is the building's first line of defence against wind loads. If the fixings fail, the panels can become detached, posing a significant risk to life and property.

Another misconception is that structural issues are only found in older buildings. Incorrect installation, such as the over-tightening of bolts or the use of incompatible metals leading to galvanic corrosion, can lead to structural concerns in relatively new developments. Furthermore, the term "structural" is sometimes conflated solely with the "primary frame." In cladding contexts, a failure of the secondary structure (the grid and brackets) is considered a structural failure of the wall system, even if the building’s main concrete or steel frame remains unaffected.

To accurately describe the structural aspects of a building envelope, several related terms are employed by professionals. These distinguish between the roles played by various components within the assembly.

TermApplication in External Walls
Primary StructureThe main load-bearing framework (e.g., concrete frame, steel columns).
Secondary StructureThe sub-frame or helping-hand system that supports the cladding panels.
Dead LoadThe static weight of the cladding panels, rails, and insulation.
Wind LoadThe pressure or suction exerted on the building face by air movement.
SubstrateThe surface (e.g., masonry, SFS, or timber) to which the cladding is fixed.
Load PathThe route by which loads are transferred from the cladding to the foundations.

These terms form the basis of technical communication between structural engineers, architects, and cladding specialists. Ensuring that each component within the load path is correctly specified and installed is a fundamental requirement for the durability and safety of the building fabric.