Non-combustible

In short
a material that does not burn or contribute significantly to fire
Non-combustible refers to building materials that do not burn or contribute significantly to fire. In the UK cladding industry, this term identifies materials classified as Euroclass A1 or A2, which are essential for high-rise external wall safety and regulatory compliance.
Last updated
On this page
Non-combustible
Definition and Fundamental Principles
In the context of the UK construction and fire safety sectors, the term "non-combustible" refers to a material that does not burn or contribute significantly to fire. This definition is not merely descriptive but is rooted in specific performance criteria defined by British and European standards. A non-combustible material is one that, when subjected to intense heat under controlled laboratory conditions, does not undergo combustion, produce significant heat, or support the spread of flame.
Within the testing framework, non-combustibility is typically determined through a suite of rigorous tests, such as the non-combustibility test (BS EN ISO 1182) and the determination of the heat of combustion (BS EN ISO 1716). These tests measure the material's reaction to fire, rather than the fire resistance of a complete assembly. In technical terms, non-combustible materials are classified as Class A1 or A2 under the European classification system (Euroclasses), as set out in BS EN 13501-1.
The Role of Non-Combustibility in External Wall Systems
External wall systems, or cladding, are complex assemblies comprising multiple layers, including the outer rainscreen, insulation, cavity barriers, and the structural backing wall. The term non-combustible is frequently applied to individual components within these systems. For example, materials such as stone, concrete, masonry, and certain mineral wool insulations are inherently non-combustible.
The application of non-combustible materials is intended to limit the potential for fire spread across the building envelope. When a material is classified as non-combustible, it is expected to provide a negligible contribution to the fire load of the building. In the event of a fire, such materials do not fuel the flames or facilitate the rapid vertical or horizontal transmission of fire that can occur with combustible alternatives. However, the performance of the system as a whole depends on how these materials are integrated and installed.
UK Regulatory Context and Approved Document B
In England and Wales, the regulatory framework governing the use of materials in external walls is primarily set out in the Building Regulations 2010, supported by Approved Document B (Fire Safety). Following significant legislative updates in recent years, the requirements for the combustibility of materials have become more stringent, particularly for "relevant buildings" over a specific height threshold.
For buildings with a storey 18 metres or more above ground level (and, in certain contexts, 11 metres), the regulations generally require that materials forming part of the external wall construction meet the criteria for European Class A2-s1, d0 or Class A1. This is often referred to in the industry as the "combustibility ban" on certain building types, including high-rise residential blocks, hospitals, and student accommodation. The objective is to ensure that the external facade does not contribute to the external spread of fire, thereby supporting the overall life safety strategy of the building.
Implications for Building Owners and Managers
Building owners, managing agents, and Right to Manage (RTM) directors encounter the term "non-combustible" most frequently during the assessment of existing cladding systems or the specification of remedial works. When a building undergoes an EWS1 (External Wall System) assessment or a Fire Risk Appraisal of External Walls (FRAEW) under PAS 9980, the combustibility of the materials present is a primary factor in the surveyor’s evaluation.
Understanding whether a material is non-combustible is essential for determining its suitability for a specific building type and height. If an existing system contains combustible materials where non-combustible materials are now required by regulation or expected by lenders and insurers, remediation may be necessary. This process involves replacing combustible elements, such as certain types of composite panels or foam insulation, with non-combustible alternatives to align the building with current safety standards and market expectations.
Non-combustible
Distinctions in Classification
It is important to distinguish between the two primary classifications that fall under the broad "non-combustible" umbrella. While both A1 and A2 materials are often grouped together in general discussion, they have distinct technical thresholds.
| Euroclass | Description | Contribution to Fire |
|---|---|---|
| A1 | Non-combustible | No contribution to fire at any stage |
| A2 | Limited-combustibility | No significant contribution to fire |
| B - F | Combustible | Varying degrees of contribution and smoke production |
A1 materials are completely non-combustible and do not require testing for smoke production or flaming droplets. A2 materials are classified as "limited-combustibility" because they may contain a very small amount of organic content, but they are tested to ensure they do not contribute to fire growth and have strictly limited smoke (s1) and flaming droplet (d0) emissions.
Common Misunderstandings and Nuances
A frequent point of confusion in the industry is the distinction between "fire-rated" or "fire-resistant" and "non-combustible." Fire resistance refers to the ability of a complete construction assembly (such as a wall or floor) to withstand a fire for a specific period, maintaining its structural integrity and preventing the passage of heat and flames. Non-combustibility, by contrast, is a property of an individual material's reaction to fire. A material can be fire-resistant without being non-combustible, but in modern high-rise cladding, the two concepts are often managed in tandem.
Another common misunderstanding involves the use of fire-retardant treatments. A material that is naturally combustible, such as timber, may be treated with chemicals to improve its reaction to fire, achieving a Class B rating. However, such treatments do not make the material non-combustible. Under current UK regulations for high-rise buildings, fire-retardant treated combustible materials are generally not permitted as substitutes for A1 or A2 rated components in the external wall.
Professional Assessment and Compliance
The determination of whether a material is non-combustible cannot be made through visual inspection alone. It requires manufacturer certification, underpinned by independent testing from UKAS-accredited laboratories. For existing buildings where documentation may be missing, intrusive sampling and laboratory testing are often required to confirm the classification of the materials used in the external wall system.
Because the regulatory environment is subject to periodic updates and involves complex intersections between the Building Safety Act, the Fire Safety Act, and various British Standards, it is essential that building professionals—including fire engineers, building surveyors, and facade consultants—carry out these assessments. They must consider not only the individual materials but also how they interact within the specific geometry and construction of the building in question to ensure a holistic approach to fire safety.